Facade Systems
Expsoed Fastener Rainscreen System
System Depth = 1” + Universe Adjustable framing
Joint Width = 3/8”
 
System Components:
1.    Trespa® Meteon® Panel
2.    Universe Slotted Aluminum Z-Extrusion – Black Color
3.    Universe Slotted Aluminum Hat Extrusion – Black Color
4.    Extrusion Fastener
5.    Panel Fastener
6.    1/4” Thermal Isolator
7.    Adjustable Angle Bracket
8.    Adjustable Angle Fastener
9.    Universe Adjustable Angle Extrusion
10.    Adjustable Angle Extrusion Fastener
11.    Thermal Isolator #1
12.    Thermal Isolator #2
13.    Mineral Wool Insulation
14.    Air & Moisture Barrier
15.    CMU
 
Notes:
•    Horizontally attached across framing.
•    Insulation (13) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed. It must be the same depth as the adjustable framing (7) (9).
•    Air & Moisture barrier (14) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB if mineral wool is less than 2” thick; if mineral wool is thicker than 2” then other barriers may be used.
•    Extrusions (2) (3) have ventilation slotting and splices for support between studs.
•    The adjustable framing (7) (9) is not painted.
•    Painted and decorative panel fasteners (5) are available for a premium.