Facade Systems
Concealed Fastener Rainscreen System
System Depth = 1 1/4” +  Universe Continuous Insulation System (1” to 3” thick as indicated on drawings)
Joint Width = 3/8”
 
System Components:
1.    Trespa® Meteon® Panel
2.    Universe Aluminum Rail – Black Color
3.    Fixed Bracket (Shop Attached)
4.    Adjustable Bracket (Shop Attached)
5.    Continuous Insulation Vertical Wide-Faced Hat Extrusion Framing
6.    Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
7.    Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
8.    Air & Moisture Barrier
9.    Sheathing
10.    16 Gauge Min. Steel Stud
 
Notes:
•    Available with 10mm and 13mm Trespa Meteon (1) panel thickness only.
•    The framing (5) is not painted.
•    Insulation (7) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool in order to be NFPA-285 fire code compliant and provide the required rigidity for the framing to attach against. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.