Concealed Fastener Rainscreen System
System Depth = 2 1/4” + Zee Girt
Joint Width = 3/8”
Joint Width = 3/8”
System Components:
1. Trespa® Meteon® Panel
2. Universe Aluminum J-Extrusion – Black Color
3. Universe Aluminum Rail – Black Color
4. Extrusion Fastener
5. Fixed Bracket (Shop Attached)
6. Adjustable Bracket (Shop Attached)
7. Zee Girt
8. Mineral Wool Insulation
9. Air & Moisture Barrier
10. Sheathing
11. 16 Gauge Min. Steel Stud
2. Universe Aluminum J-Extrusion – Black Color
3. Universe Aluminum Rail – Black Color
4. Extrusion Fastener
5. Fixed Bracket (Shop Attached)
6. Adjustable Bracket (Shop Attached)
7. Zee Girt
8. Mineral Wool Insulation
9. Air & Moisture Barrier
10. Sheathing
11. 16 Gauge Min. Steel Stud
Notes:
• J-Extrusions (2) are included at 32” on center for bidding purposes; if structural calculations are required, additional J-extrusions may be required.
• Available with 10mm and 13mm Trespa Meteon (1) panel thickness only.
• The zee girt (7) is not painted.
• Insulation (8) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.
• J-Extrusions (2) are included at 32” on center for bidding purposes; if structural calculations are required, additional J-extrusions may be required.
• Available with 10mm and 13mm Trespa Meteon (1) panel thickness only.
• The zee girt (7) is not painted.
• Insulation (8) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.