Facade Systems
Concealed Fastener Rainscreen System
System Depth = 1 1/2” + Universe Adjustable framing
Joint Width = 3/8”
 
System Components:
1.    Trespa®  Meteon® Panel
2.    Universe Hanger Rail Extrusion – Black Color (Shop Attached)
3.    Universe Intermediate Rail Extrusion – Black Color
4.    Extrusion Fastener
5.    Fixed Bracket (Shop Attached)
6.    (2) 1/4” Thermal Isolators
7.    Adjustable Angle Bracket
8.    Adjustable Angle Fastener
9.    UNIVERSE® Adjustable Angle Extrusion
10.    Adjustable Angle Extrusion Fastener
11.    Thermal Isolator #1
12.    Thermal Isolator #2
13.    Mineral Wool Insulation
14.    Air & Moisture Barrier
15.    CMU
 
Notes:
•    Horizontally attached across framing.
•    Thermal Isolators (6) are required at each Fixed Bracket Clip (5).
•    Insulation (13) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.  The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed. It must be the same depth as the adjustable framing (7) (9).
•    Air & Moisture barrier (11) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB if mineral wool (10) is less than 2” thick; if mineral wool is thicker than 2” then other barriers may be used.
•    Extrusions have splices for support between studs.
•    Available with 10mm and 13mm Trespa Meteon (1) panel thickness only.
•    The adjustable framing (7) (9) is not painted.