Exposed Fastener Rainscreen System
System Depth = 1” + Universe Continuous Insulation System (1” to 3” thick as indicated on drawings)
Joint Width = 3/8”
Joint Width = 3/8”
System Components:
1. Trespa® Meteon® Panel
2. Universe Aluminum J-Extrusion – Black Color
3. Universe Aluminum Hat-Extrusion – Black Color
4. Extrusion Fastener
5. Panel Fastener
6. Continuous Insulation Horizontal Wide-Faced Hat Extrusion Framing
7. Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
8. Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
9. Air & Moisture Barrier
10. Sheathing
11. 16 Gauge Min. Steel Stud
2. Universe Aluminum J-Extrusion – Black Color
3. Universe Aluminum Hat-Extrusion – Black Color
4. Extrusion Fastener
5. Panel Fastener
6. Continuous Insulation Horizontal Wide-Faced Hat Extrusion Framing
7. Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
8. Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
9. Air & Moisture Barrier
10. Sheathing
11. 16 Gauge Min. Steel Stud
Notes:
• Vertically attached.
• Air & Moisture barrier (9) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB if mineral wool (9) is less than 2” thick; if mineral wool is thicker than 2” then other barriers may be used.
• The framing (6) is not painted.
• Painted and decorative Panel Fasteners (5) are available for a premium.
• Insulation (8) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool in order to be NFPA-285 fire code compliant and provide the required rigidity for the framing to attach against. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.
• Vertically attached.
• Air & Moisture barrier (9) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB if mineral wool (9) is less than 2” thick; if mineral wool is thicker than 2” then other barriers may be used.
• The framing (6) is not painted.
• Painted and decorative Panel Fasteners (5) are available for a premium.
• Insulation (8) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool in order to be NFPA-285 fire code compliant and provide the required rigidity for the framing to attach against. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.