Facade Systems
Exposed Fastener Rainscreen System
System Depth = 1 1/4” + Universe Adjustable framing
Joint Width = 3/8”
 
System Components:
1.    TRESPA® Meteon® Panel
2.    Aluminum Z-Extrusion – Black Color
3.    Aluminum Hat Extrusion – Black Color
4.    Extrusion Fastener
5.    Panel Fastener
6.    (2) 1/4” Thermal Isolators
7.    Adjustable Angle Bracket
8.    Adjustable Angle Fastener
9.    Adjustable Angle Extrusion
10.    Adjustable Angle Extrusion Fastener
11.    Thermal Isolator #1
12.    Thermal Isolator #2
13.    Mineral Wool Insulation
14.    Air & Moisture Barrier
15.    CMU
 
Notes:
•    Horizontally attached across framing.
•    Thermal Isolators (6) are included to allow ventilation; they are not necessary if the vertical frame extends ½” (min) past the insulation to create free-air vent space.
•    The adjustable framing (7) (9) is not painted.
•    Painted and decorative panel fasteners (5) are available for a premium.
•    Insulation (13) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.  The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.