Facade Systems
Exposed Fastener Rainscreen System
System Depth = 1 1/4” + Zee Girt
Joint Width = 3/8”
 
System Components:
1.    Trespa® Meteon® Panel
2.    Universe Aluminum Z-Extrusion – Black Color
3.    Universe Aluminum Hat Extrusion – Black Color
4.    Extrusion Fastener
5.    Panel Fastener
6.    (2) 1/4” Thermal Isolators
7.    Zee Girt
8.    Mineral Wool Insulation
9.    Air and Moisture Barrier
10.    Sheathing
11.    16 Gauge Min. Steel Stud
 
Notes:
•    Horizontally attached across framing.
•    Thermal Isolators (6) are included to allow ventilation; they are not necessary if the vertical framing extends ½” (min) past the insulation to create free-air vent space 
•    The zee girt (7) is not painted.
•    Painted and decorative panel fasteners (5) are available for a premium.
•    Insulation (8) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.  The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.