Exposed Fastener Rainscreen System
System Depth = 1 1/4” + Zee Girt
Joint Width = 3/8”
System Components:
1. Trespa® Meteon® Panel
2. Universe Aluminum Z-Extrusion – Black Color
3. Universe Aluminum Hat Extrusion – Black Color
4. Extrusion Fastener
5. Panel Fastener
6. (2) 1/4” Thermal Isolators
7. Zee Girt
8. Mineral Wool Insulation
9. Air and Moisture Barrier
10. Sheathing
11. 16 Gauge Min. Steel Stud
2. Universe Aluminum Z-Extrusion – Black Color
3. Universe Aluminum Hat Extrusion – Black Color
4. Extrusion Fastener
5. Panel Fastener
6. (2) 1/4” Thermal Isolators
7. Zee Girt
8. Mineral Wool Insulation
9. Air and Moisture Barrier
10. Sheathing
11. 16 Gauge Min. Steel Stud
Notes:
• Horizontally attached across framing.
• Thermal Isolators (6) are included to allow ventilation; they are not necessary if the vertical framing extends ½” (min) past the insulation to create free-air vent space
• The zee girt (7) is not painted.
• Painted and decorative panel fasteners (5) are available for a premium.
• Insulation (8) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.
• Horizontally attached across framing.
• Thermal Isolators (6) are included to allow ventilation; they are not necessary if the vertical framing extends ½” (min) past the insulation to create free-air vent space
• The zee girt (7) is not painted.
• Painted and decorative panel fasteners (5) are available for a premium.
• Insulation (8) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.