Facade Systems
*Details showing this sub-framing are not available at this time.
Wet Seal System
System Depth = 1 ¼” +  Universe Continuous Insulation System (1” to 3” thick as indicated on drawings)
Joint Width = 1/2”
 
System Components:
1.    ALPOLIC® Panel
2.    Universe Panel Extrusion
3.    Extrusion Fastener
4.    Extruded Backer Rod
5.    Backer Rod Fastener
6.    Joint Sealant
7.    Aluminum Stiffener
8.    Structural Adhesive
9.    ¼” Thermal Isolator
10.    Continuous Insulation Vertical Aluminum Tube Framing
11.    Aluminum Tube Framing Fastener; attaches through insulation to substrate
12.    Polyisocyanurate Insulation
13.    Line of Structure
 
Notes:
•    Field applied joint sealant (6) is required for the system to be weather tight.
•    Non-Progressive Installation – allows for individual panel replacement and allows sequence flexibility.
•    Economical and versatile system adaptable to complex designs.
•    System has passed air, water and structural tests.
•    For steel stud construction, 16 gauge min. is required.
•    Insulation (12) must be polyisocyanurate in order to be NFPA-285 fire code compliant and provide the required rigidity for the framing to attach against.