Facade Systems
Concealed Fastener Rainscreen System
System Depth = 1 1/2” + Zee Girt
Joint Width = 3/8”
 
System Components:
1.    Trespa®  Meteon® Panel
2.    Universe Hanger Rail Extrusion – Black Color (Shop Attached)
3.    Universe Intermediate Rail Extrusion – Black Color
4.    Extrusion Fastener
5.    Fixed Bracket (Shop Attached)
6.    (2) 1/4” Thermal Isolators
7.    Zee Girt
8.    Mineral Wool Insulation
9.    Air & Moisture Barrier
10.    CMU
 
Notes:
•    Horizontally attached across framing.
•    Thermal Isolators (6) are required at each Fixed Bracket Clip (5).
•    Insulation (8) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.  The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed. It must be must be the same depth as the zee girt (7).
•    Air & Moisture barrier (9) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB if mineral wool (8) is less than 2” thick; if mineral wool is thicker than 2” then other barriers may be used.
•    Available with 10mm and 13mm Trespa Meteon (1) panel thickness only.
•    The zee girt (7) is not painted.