Facade Systems
Exposed Fastener Rainscreen System
System Depth = 1” + Universe Adjustable framing
Joint Width = 3/8”
 
System Components:
1.    Trespa® Meteon® Panel
2.    Universe Aluminum J-Extrusion – Black Color
3.    Universe Aluminum Running Bond Extrusion – Black Color
4.    Extrusion Fastener
5.    Panel Fastener
6.    Adjustable Angle Bracket
7.    Adjustable Angle Fastener
8.    Universe Adjustable Angle Extrusion
9.    Adjustable Angle Extrusion Fastener
10.    Thermal Isolator #1
11.    Thermal Isolator #2
12.    Mineral Wool Insulation
13.    Air & Moisture Barrier
14.    Sheathing
15.    16 Gauge Min. Steel Stud
 
Notes:
•    Vertically attached.
•    Mineral wool insulation (12) is required and must be the same depth as the adjustable framing (6) (8).
•    Air & Moisture barrier (13) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB if mineral wool is less than 2” thick; if mineral wool is thicker than 2” then other barriers may be used.
•    The adjustable framing (6) (8) is not painted.
•    Painted and decorative panel fasteners (5) are available for a premium.