Concealed Fastener Rainscreen System
System Depth = 1 3/4” + Universe Continuous Insulation System (1” to 3” thick as indicated on drawings)
Joint Width = 3/8”
Joint Width = 3/8”
System Components:
1. EQUITONE Panel
2. Universe Hanger Rail Extrusion – Black Color
3. Extrusion Fastener
4. Fixed Bracket (Shop Attached)
5. Adjustable Bracket (Shop Attached)
6. Tergo+ Secret Fix Undercut Anchor (Shop Attached)
7. 1/4” Thermal Isolator
8. Continuous Insulation Vertical Wide-Faced Hat Extrusion Framing
9. Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
10. Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
11. Air & Moisture Barrier
12. Sheathing
13. 16 Gauge Min. Steel Stud
2. Universe Hanger Rail Extrusion – Black Color
3. Extrusion Fastener
4. Fixed Bracket (Shop Attached)
5. Adjustable Bracket (Shop Attached)
6. Tergo+ Secret Fix Undercut Anchor (Shop Attached)
7. 1/4” Thermal Isolator
8. Continuous Insulation Vertical Wide-Faced Hat Extrusion Framing
9. Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
10. Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
11. Air & Moisture Barrier
12. Sheathing
13. 16 Gauge Min. Steel Stud
Notes:
• 12mm thickness is required for [natura], [materia] and [pictura] material; 8mm thickness can be used for [tectiva] material.
• Horizontally attached across framing.
• Extrusions have splices for support between studs.
• Insulation (10) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.
• 12mm thickness is required for [natura], [materia] and [pictura] material; 8mm thickness can be used for [tectiva] material.
• Horizontally attached across framing.
• Extrusions have splices for support between studs.
• Insulation (10) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.