Exposed Fastener Rainscreen System
System Depth = 1 1/4” + Universe Continuous Insulation System (1” to 3” thick as indicated on drawings)
Joint Width = 3/8”
System Depth = 1 1/4” + Universe Continuous Insulation System (1” to 3” thick as indicated on drawings)
Joint Width = 3/8”
System Components:
1. EQUITONE Panel
2. Universe Aluminum Z-Extrusion - Black Color
3. Universe Aluminum Hat Extrusion – Black Color
4. Extrusion Fastener
5. Panel Rivet – Color Matched
6. Foam Tape (Shop Attached)
7. (2) 1/4” Thermal Isolators
8. Continuous Insulation Vertical Wide-Faced Hat Framing
9. Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
10. Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
11. Air and Moisture Barrier
12. Sheathing
13. 16 Gauge Min. Steel Stud
2. Universe Aluminum Z-Extrusion - Black Color
3. Universe Aluminum Hat Extrusion – Black Color
4. Extrusion Fastener
5. Panel Rivet – Color Matched
6. Foam Tape (Shop Attached)
7. (2) 1/4” Thermal Isolators
8. Continuous Insulation Vertical Wide-Faced Hat Framing
9. Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
10. Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
11. Air and Moisture Barrier
12. Sheathing
13. 16 Gauge Min. Steel Stud
Notes:
• Horizontally attached across framing.
• Thermal Isolators (7) are included, as required, to allow ventilation; they are not necessary if the vertical framing extends ½” (min) past the insulation to create free-air vent space.
• The framing (8) is not painted.
• Insulation (10) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool. The insulation must also be in-between the vertical wide-faced hat extrusions (9) to meet NFPA-285 fire code. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.
• Horizontally attached across framing.
• Thermal Isolators (7) are included, as required, to allow ventilation; they are not necessary if the vertical framing extends ½” (min) past the insulation to create free-air vent space.
• The framing (8) is not painted.
• Insulation (10) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool. The insulation must also be in-between the vertical wide-faced hat extrusions (9) to meet NFPA-285 fire code. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.